Beam detector installation manual

Alignment is easily accomplished with an optical sight and a twodigit signal strength meter incorporated into the beam detector. Optical smoke beam detector conventional fire systems eaton. The relatively broad angle of the ir beam eases adjustment and guarantees reliable longterm stability. Please refer to the beamhkr installation manual for operation instructions. For ranges between 50m and 100m, use a 100m detector with 4 reflectors. Receiver installation procedure ribbon cable installation to beam detector. Mounting tips usually, the detector and the reflector are installed at the same height and oriented towards each other. With the use of cmos imaging technology osid not only provides reliable smoke detection but has been designed for rapid installation and reliable operation during the life time of the detector. Reflective optical beam smoke detector user guide safelincs. Installation of the singleended reflective design is much quicker than a dualended projected beam detector. Installation and maintenance instructions fsb200, fsb200s singleended reflected type projected beam smoke detector 12 clintonville rd. System sensor beam detector is a fourwire conventional reflected beam smoke detector, which is uniquely suited for protecting open areas with high ceilings, where other methods of smoke detection are difficult to install and maintain. The new simplex addressable beam detector combines the power and flexibility of idnet technology with the proven performance of the fireray 5000 optical beam smoke detector.

The projected beam type smoke detector shall be listed to u. Installation instructions ds474qi and ds476qi quad beam. Read this instruction manual carefully prior to installation. One optical beam detector will generally replace as many as 16 single spot detectors covering 1500msq. Installation and maintenance instructions beam1224, beam1224s singleended reflected type projected beam smoke detector 3825 ohio avenue, st. Though this information is based upon industry expertise, it is intended to. The osid range of openarea smoke detectors deliver a great package for reliable smoke detection in large or open spaces. It explains how it works, the features you get as standard, as well as information about our kits and accessories. Installation manual fireray 3000 bosch security systems. For ranges between 50m and 100m, use a 100m detector. The real truth about where to install smoke and c o detectors duration.

Please follow the instructions in this step if you have chosen to secure the detector component to the mounting. A trouble signal is generated if the beam is more than 90% obstructed as opposed to partially obscured by smoke for. This installation sheet provides information on how to install the osid smoke detection system. The infrared beam path must be kept clear of obstructions at all times. Osidr reflective imaging smoke beam detector duration. Do not use the product for purposes other than the detection of moving objects such as people and. Edwards signaling ec50r 100r reflective beam smoke.

Installation and operation manual fire alarm and fire. The abd2f is an addressable projected beam smoke sensor. Prior to selecting this item ensure the beam is properly aligned and the reflector is uncovered. Never mount a detector to a suspended support, such as a pipe or length of wood that is supported at only one end. Smoke detection if smoke is present in the beam, the received signal is reduced by a level determined by the. Rotate the alignment tool 90 clockwise to lock the sphere into. How to install infrared beam sensors for gate and drive alert duration. The abdrt2f is an addressable projected beam smoke sensor with integrated sesitivity testing. Thread the 10 way ribbon cable through the back of the beam detector, so that the connector. Fsosiria addressable reflective beam smoke detector. Skbeam, skbeamt singleended reflected type projected.

Installation, commissioning and operator handbook products. Ul listed products must comply with nfpa72 ensure clear line of sight between detector and reflector it is recommended at least 0. Singleended reflected type projected beam smoke detector. The abd2fabdrt2f is uniquely suited to sense smoke in hostile environments or open areas with high ceilings where spot type sensors are not suitable or dificult to install and maintain. G 297058 to en54 part 12 fireray 2000 installation guide 22318. Awbk901 conventional reflective beam detector asenware ltd page 2 product safety to prevent severe injury and loss of life or property, read the instruction carefully before installing the beam detector to ensure proper and safe operation of the system. The detector base has four primary mounting holes, one in each corner of the base. Reflected beam smoke detectors are designed for spacious rooms, open areas, and high ceilings.

A beam detector is a fire alarm detection device that projects a beam of light across a large area to detect smoke. Beam smoke detectors depend on the projected beam measurement to sense smoke. Bosch d296 installation instructions manual hb t001s8 solar powered multi beam active wireless infrared csmdtn dual technology motion detector cosmos dt user manual d9105exd manualzz i56 2294 005r fire lite alarms by honeywell. Beam1224, beam1224s singleended reflected type projected. Hochiki spbet beam detector user manual 230294iss2feb2001 11 2. Osid by xtralis your beam detector replacement fire. In order to mount the detector to the wall, the outer cover must be removed after unscrewing its four retaining screws.

Installation missioning and operator hand fireray 100r 330 foot reflective beam detector c tec trade fireray accessories sheet k85001 0616 ec5000r reflective beam detector. Trouble or alarm conditions can be caused by shifts in beam alignment when the transmitter or receiver moves. With only one device to install and align, these singleended optical beam solutions saves you time and money on large area applications. Installation instructions d296 and d297 long range beam smoke detectors 1. The transmitter emits an invisible infrared light beam that is reflected via a prism mounted directly opposite and with a clear line of sight. Extremely simple to install, the beam detector requires no separate power supply and features an easy alignment installation process. How to install infrared detection beams 40m calibration shown. Unlike traditional detection systems, reflected beam smoke detectors were designed for spacious rooms, open areas, and high ceilings. Application notes for indoor use only for wall mounting only do not install in locations where the normal ambient. The beam will start by raising its sensitivity first and can rise all the way up to 100%, after this the output power will rise. Detector installation must comply with local regulations. The fire beam brochure contains detailed information on the range of fire beam products.

The signal is reflected by a prism and analysed for smoke presence. Installation instructions linear smoke detector fireray 50100rv stpmfzab 610f. Guide to using optical beam smoke detection optical. Since the sudden and total obscuration of the light beam is not a typical smoke signature, the detector sees this as a trouble condition, not an alarm. How to video for nfxi beam detectors installation and alignment. System sensor beam detector, beam detector honeywell. View and download honeywell firelite beam355 installation and maintenance instructions manual online. Do not install the detector or reflector in environments where condensation or icing are likely to occur for ranges between 5m and 50m, use a 50m detector with 1 reflector.

All four holes must be used to provide secure mounting. Detector settings this option allows the installer to make changes to the detectors operating parameters 9 set zero 100% this option is selected by pressing the tick key. Fireray 5000 beam detector installation manual new. Spc24 projected beam smoke detector operation, continued when there is a difference between actual beam strength and stored reference data that exceeds the programmed alarm obscuration reference level, a fire signal is produced. The notifier fsb200 and fsb200s are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wideopen areas, where spottype smoke detectors are difficult to install and maintain. Installation instructions d296 and d297 long range beam. Esp firebeam installation manual page 9 of 19 2011 hochiki europe uk ltd 23040iss2dec11 receiver sensitivity starts off at 5% and output power starts at 10%. Generalinformation 30cm 30cm transmitter receiver power supplyunit controller 5120m. This detector offers cost effective protection of large, open area spaces with high ceilings. Beam detectors are used to provide open area smoke detection in situations where it is either impractical or not cost effective to use traditional pointtype. Beamhkr the beamhkr allows the reflector to operate in environments prone to the formation of condensation. The system is designed to be mounted so that the beam will project between 0. The remote test accessory allows for the beam detector.

These devices are typically installed in large areas where spot type smoke detection is not practical due to cost or location. Detector placement this section of the manual discusses the placement of projected beam detectors. The osiriss is a singleended, reflected type beam smoke detector that includes an 8 reflector and an integral sensitivity test. Point detection is often used but can lead to a complex network of many overlapping sensors which will be very time consuming to install, expensive to wire and could be problematical to access when maintaining.